Nuclear fusion is considered by many as the energy of the future: it produces immense amounts of energy in a much safer way than nuclear fission, and the availability of its fuels (deuterium and tritium) is virtually unlimited. However, nuclear fusion remains experimental, and significant scientific and engineering advances are still required to achieve commercial power generation. There are two main magnetic-confinement fusion concepts: tokamaks and stellarators. Both confine plasma in a toroidal magnetic field, but tokamaks require a large plasma current, whereas stellarators generate the confining field entirely with external coils. Most fusion devices worldwide are tokamaks (for example ITER in France), but stellarators offer advantages for steady-state operation and are therefore the subject of intensive research.
One of the most important fusion research facilities in the world is located in Greifswald, Germany: it’s called Wendelstein 7-X, it is run by the Max Planck Institute for Plasma Physics (IPP), and it is the world’s largest fusion device of the stellarator type.
We spoke with Rico Schwibbe, Radiation Protection Officer at Wendelstein 7-X, about how Berthold Technologies' radiation protection solutions have been supporting the facility since 2014.
What were the main requirements of the project?
We monitor both neutron and gamma radiation across the facility. There are two key areas that require monitoring: the torus hall, where radiation is generated during operation, and the surrounding areas of the facility.
Inside the torus hall, it is essential that the radiation probes can recover quickly and reliably from saturation after experiments, as access to the radiation protection areas following an experiment depends on the readings from the gamma probes in the torus hall. In the rest of the facility, although the hall is surrounded by 1.8-meter-thick concrete shielding on all sides, radiation monitoring is also required. The objective is to ensure that the annual dose rate limit of 1 mSv is not exceeded, which requires the use of highly sensitive probes capable of measuring very low dose rates.
In total, we required 20 radiation probes, including both neutron and gamma detectors. Two gamma probes and one neutron probe were installed inside the torus hall, while the remaining units were distributed around the exterior of the hall on different floor levels. They were strategically positioned in locations where we wanted to verify the effectiveness of the concrete shielding and ensure that the dose rate limit of 1 mSv per year is not exceeded.
Another important requirement was the ability to process and visualize measurement data within our existing control system software.

Download the full customer story to learn more about the solution offered by Berthold and how it fulfilled the requirements of this project!

Need help to choose the best radiation protection solutions for your project?
Wait no more, our specialists will be glad to help you!