Microwave Moisture Analyzer LB 567/LB 568

MicroPolar is the latest online moisture analyzer, using state-of-the-art microwave transmission technology. The moisture measurement is carried out non-contacting, either on a conveyor belt or in a chute.

Without contact to the measured material, the sensors are not subject to wear and tear and even maintenance is not required at any time.

Typical fields of applications are to be found in the mining industry and power plants, in the chemical, pulp & paper and building materials industries.

Measuring Principle

The representative microwave transmission technology, penetrating the whole material cross-section, allows for the high accuracy and reliability of the system. 

Learn more about our Moisture Gauges

MicroPolar 2 LB 567 System Highlights

MicroPolar 2 LB 567 is predestined for applications with constant measuring conditions (e.g. constant particle size, bulk density etc.) The measurement is carried out without the need of a radiometric unit. In combination with a height sensor the system allows for a compensation of varying bulk heights on the conveyor belt. For more demanding applications however, we recommend to use the moisture sensor MicroPolar Moist LB 568

MicroPolar Moist LB 568 System Highlights

The moisture analyzer MicroPolar Moist LB 568 is applied when the bulk density varies. Beside the moisture measurement by microwaves the system comprises also a radiometric unit to measure the area weight (mass per unit area). By combining both measurements varying bulk densities can be reliably compensated leading to a significantly improved measurement accuracy.

Tabs

Features

Multi-frequency Technology

The measurement is performed with a number of different frequencies per measurement cycle, leading to a very stable and reliable measurement, unaffected by reflexes or resonances.

High Dynamics

The high dynamic range of Micro-Polar allows the precise determination of moisture on even very high bulk loads.

Height Compensation

If the bulk height varies, a separate distance sensor can be connected, ensuring highly accurate measuring results.

Area weight Compensation

Varying particle sizes can affect the measurement performance. Using the radiometric area weight compensation the fluctuating bulk density is reliable compensated and optimum measuring accuracy is achieved.

Reference Line

An integrated reference line makes the measurement independent from potential environmental influences.

Automatic on-site Calibration

The calibration is done directly on the evaluation unit. The software contains a sample taking feature, where laboratory values can be easily entered and linked to the corresonding measurement values. The calibration curve is calculated automatically.

System Configuration

Arrangement on a conveyor belt

With the emitting antenna mounted beneath and the receiving antenna mounted above the conveyor belt, the microwaves can penetrate the whole material interface.

Arrangement on a chute

The antennas are mounted on opposite sides at the outer wall of the chute. The microwaves are able to penetrate the walls of the chute as long as they are not made from conductive material. In that case a window made of plastic material may help, alternatively our measuring chute can be used (see picture below).

 

 

 

Specifications
Technical Data 

MicroPolar control units

 

Method

Microwave transmission measurement

Transmitting power

<10 mW (<10 dBm), coaxial output power, depends on the
particular type

Housing

Wall mounted housing made of stainless steel
LB 566: HxWxD: 300x323x140 mm
LB 566 ++ / LB 567 ++ / LB 568: 400x338x170 mm

Protection class

IP 65

Ambient temperature

Operation:

- LB 566 (++): –20 ... 60 °C (–4 ... 140 °F)
- LB 567: –20...50 °C (–4 ... 122 °F)
- LB 567 ++, LB 568: –20 ... 45 °C (–4 ... 113 °F)

Storage:

All versions: –20 ... 60 °C (4 ... 140 °F)
Operation and storage without condensation

Achievable precision

≤ 0.1 weight %
(standard deviation

Power supply

All versions: 100 ... 240 V AC, 50/60 Hz
LB 566 ++, LB 567 (++), LB 568: 24 V DC
LB 566: 24 V AC /DC

Power consumption

Max. (48/60) VA (AC/DC)

Software languages

English, German, French

Inputs and outputs

 

Sensor connection

Inputs and outputs for HF cable
(measurement and reference channel)

Current input

2 x current input 0/4...20 mA: Impedance 50 Ω,1x insulated,
1x device earth e.g. temperature compensation,
loading height compensation

Current output

Current output 1: 4 ... 20 mA, max. impedance 800 Ω,
insulated, for measured value

Current output 2: 0/4 ... 20 mA, max. impedance 800 Ω,
insulated, e.g. for temperature, density etc.

Pt100 connection

Measurement range: –50 ... 200 °C (–58 ... 392 °F) for
temperature compensation

Digital input

3 x digital inputs, functions: Start/Stop measurement, keep
measurement, product range, test sample

Relay outputs

2 x relays, SPST, insulated, functions: Collective malfunction notification,
pause measurement, threshold value (min. and max.), loading shortfall

Serial interface

For general data output (set-up, commissioning protocol,
measured value) and software update

All versions: RS232 (connection to memory tool or PC)
LB 566 (++), LB 567 (++): RS485

  

 

Download
Application Report
Format Size
Concentration Measurement for milk of lime en PDF 275.59 KB
Dry Substance & Water Content Process monitoring in dairy production en PDF 537.78 KB
Moisture on Bales of Lucerne, Tobacco and others en PDF 517.46 KB
Online Moisture Measurement for Wood Chips en PDF 243.01 KB
Real time Measurement of moisture in wood chips and pellets Press Release in Bioenergy Insight en PDF 186.6 KB
Solution for Pulp and Paper Production Mass Flow, Density Measurement, Level and Moisture Measurement de, en PDF 1.37 MB
Brochure
Format Size
Microwave Measurement Moisture, dry substance and concentration en PDF 1.77 MB
Operation Manual
Format Size
LB 567 MicroPolar 2 (++) User’s Guide - Hardware Manual / 41988BA2 Rev. Nr.: 05, 03/2018 en PDF 7.46 MB
LB 568 Micro-Polar Moist en PDF 6.08 MB
MemoryTool Manual/BA de, en PDF 659.87 KB
Press & Media
Format Size
Real time measurement of moisture in biomass by Graeme Webb, Forest Bioenergy Review, Spring 2016 en PDF 980.52 KB
Product Information
Format Size
Determination of Carbon in Fly-Ash en PDF 760.11 KB
Project Questionnaire
Format Size
Concentration & Moisture Measurement with Microwave Systems en PDF 14.74 KB
Software Tool
Format Size
Software for the LB 567 en ZIP 551.06 KB
Software for the LB 568 en ZIP 552.52 KB
Technical Information
Format Size
LB 567 MicroPolar de, en PDF 4.06 MB
LB 568 MicroPolar Moist de, en PDF 2.12 MB